OCM-141 Portable Multifunction Calibrator
Multifunction calibrator is designed for use in
calibration laboratories, quality departments and production lines
as a standard for electric quantity meters testing.
With model M-141 calibration of voltmeters to 700 V, ammeters to 2 A,
resistance ranges of multimeters and industrial evaluation units
can be performed easily. Interface RS-232 enables to add the
calibrator to the automated calibration and testing systems.
Model M-141 can work under Meatest application SW like WinQbase
and Caliber.
Key Features
- Voltage range from 0 to 700 V DC/AC with uncertainty 0.01 %
- Current range from 0 to 2 A DC/AC with uncertainty 0.02 %
- Sinusoidal output signal
- Fix standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %
- TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
|
- Cold junction point automatic compensation with external Pt100 sensor
- Power supply voltage 115/230V 50/60 Hz
- Interface RS 232, IEEE488 (on request)
- Comfortable control, large display
- Weight 5 kg
|
OCM-141 Specifications (Preliminary)
DC/AC voltage
| range |
% of value
+ % of range |
% of value
+ % of range |
% of value
+ % of range |
| |
DC |
20 Hz - 200 Hz |
200 Hz - 1000 Hz |
| 0 mV - 10 mV * |
0.05 + 0.0 + 10 µV |
0.20 + 0.05 + 20 µV |
0.20 + 0.10 + 20 µV |
| 10mV - 100mV |
0.01 + 0.001 + 10 µV |
0.10 + 0.03 + 20 µV |
0.15 + 0.05 + 20 µV |
| 100 mV - 1 V |
0.008 + 0.002 |
0.05 + 0.005 |
0.07 + 0.01 |
| 1 V - 10 V |
0.008 + 0.002 |
0.05 + 0.005 |
0.07 + 0.03 |
| 10 V - 100 V |
0.015 + 0.004 |
0.05 + 0.01 |
0.07 + 0.03 |
| 100 V - 700 V |
0.018 + 0.004 |
0.03 + 0.02 |
0.10 + 0.03 |
* DC voltage from 0 µV, AC voltage from 1 mV
|
DC/AC current
| range |
% of value + % of
range |
% of value + % of
range |
% of value + % of
range |
| |
DC |
20 Hz - 200 Hz |
200 Hz - 1000 Hz |
| 1 µA - 200 µA |
0.05 + 0.0 + 20 nA |
0.25 + 0.0 + 20 nA |
0.30 + 0.10 + 20 nA |
| 200 µA - 2 mA |
0.025 + 0.005 |
0.10 + 0.01 |
0.20 + 0.05 |
| 2 mA - 20 mA |
0.015 + 0.003 |
0.07 + 0.005 |
0.20 + 0.05 |
| 20 mA - 200 mA |
0.015 + 0.003 |
0.07 + 0.005 |
0.20 + 0.05 |
| 200 mA - 2 A |
0.015 + 0.005 |
0.1 + 0.005 |
0.25 + 0.05 |
When option 140-50 Current coil is used, add uncertainty 0.3 % of the set current to the value specified in the above table. Output current is multiplied by factor 25/50.
|
TC temperature sensor simulation
| types |
R, S, B, J, T, E, K, N |
| range of temperature |
-250 °C - 1820 °C |
| temperature uncertainty |
0.4 °C - 3.2 °C |
| temperature scale
|
ITS 90, PTS 68 |
Resistance
| Nominal value (Ohm) |
% of value |
| 10 |
0.03 + 10 mOhm |
| 100 |
0.05 |
| 1 k |
0.02 |
| 10 k |
0.02 |
| 100 k |
0.02 |
| 1 M |
0.05 |
| 10 M |
0.05 |
| 100 M |
0.2 |
Accessories (included)
| Power line cable |
1 pc |
| Operation manual |
1 pc |
| Option 10/11 : Test cable for 1000V - 20 A, black/red |
2 pcs |
Options (extra ordered)
| Option 140-50 |
Current coil with 25/50 turns. Suitable for clamp A-meters testing up to 100 A.
|
 |
| Option 10 |
Test cable 20A/1000V (black) |
|
| Option 11 |
Test cable 20A/1000V (red) |
|
| Cable RS-232 |
RS-232, 2m |
|
| WinQbase |
Application SW for making database of meters and for automatic meter calibration. |
|
| CALIBER |