Basic parameters
Basic function of the calibrator is
generating of the calibrated
DC/AC voltage in the range
from 0 µV to 1000 V and
DC/AC current in the range from
0 to 20 A . Using a 50-turn coil the current range can be
extended from 50 µA to 500 A. The best accuracy of the
calibrator on DC voltage ranges is 0.0035%, on AC voltage
ranges 0.03%, on DC current ranges 0.013% and on AC
current ranges 0.055%. Maximum frequency range is from 20
Hz to 100 kHz for harmonic output waveform.
consumption. For calibrations of the thermometers and
temperature regulators, the function of
simulation of
temperature sensors is determined. Calibrator is able to
simulate all TC sensors of the R, S, B, J, T, E, K and N types as
well. Compensation of the TC cold junction is made by entering value from the keyboard.
User comfort
M-140i Calibrator is equipped with a number of
other functions which make its use easier. Among them
belong possibility to set relative deviations from the
actual value of the selected output signal, displaying of
the output signal uncertainty, internal calibration
procedure and others. Concept of the calibrator's control
and indication uses a large area luminescence display on
which all necessary information is concentrated. The
control is perform by selection from the menu. Moreover,
frequently used functions have firmly assigned keys with
direct control. As standard calibrator is equipped with
RS-232 serial port making it possible to be controlled by personal computer.
The calibrator can be included into MEATEST´s WinQbase software calibration systems.
M-140i Specifications
DC/AC voltage
| range |
% of value
+ % of range |
% of value
+ % of range |
% of value
+ % of range |
% of value
+ % of range |
| |
DC |
20 Hz - 10 kHz |
10 kHz - 50 kHz |
50 kHz - 100 kHz |
| 0 mV - 20 mV ** |
0.05 + 0.0 + 10 µV |
0.20 + 0.05 + 20 µV |
0.20 + 0.10 + 20 µV |
0.20 + 0.10 + 20 µV |
| 20mV - 200mV |
0.01 + 0.0 + 10 µV |
0.1 + 0.03 + 20 µV |
0.15 + 0.05 + 20 µV |
0.15 + 0.05 + 20 µV |
| 200 mV - 2 V |
0.003 + 0.0008 |
0.025 + 0.005 |
0.05 + 0.01 |
0.05 + 0.01 |
| 2 V - 20 V |
0.003 + 0.0005 |
0.025 + 0.005 |
0.05 + 0.03 |
0.05 + 0.03 |
| 20 V - 240 V |
0.003 + 0.0005 |
0.025 + 0.010 |
-- |
-- |
| 240 V - 1000 V |
0.005 + 0.005 |
0.03 + 0.02 * |
-- |
-- |
* valid for f < 1000 Hz
** DC voltage from 0 µV, AC voltage from 1 mV
|
DC/AC current
| range |
% of value + % of
range |
% of value + % of
range |
% of value + % of
range |
% of value + % of
range |
| |
DC |
20 Hz - 1 kHz |
1 kHz - 5 kHz |
5 kHz - 10 kHz |
| 1 µA - 200 µA |
0.05 + 0.0 + 20 nA |
0.15 + 0.0 + 20 nA |
0.30 + 0.10 + 20 nA |
-- |
| 200 µA - 2 mA |
0.02 + 0.005 |
0.07 + 0.01 |
0.20 + 0.05 |
0.20 + 0.05 |
| 2 mA - 20 mA |
0.01 + 0.003 |
0.05 + 0.005 |
0.20 + 0.05 |
0.20 + 0.05 |
| 20 mA - 200 mA |
0.01 + 0.003 |
0.05 + 0.005 |
0.20 + 0.05 |
0.20 + 0.05 |
| 200 mA - 2 A |
0.015 + 0.005 |
0.05 + 0.005 |
-- |
-- |
| 2 A - 20 A |
0.02 + 0.010 |
0.10 + 0.03 |
-- |
-- |
When option 130-50 Current coil is used, add uncertainty 0.3 % of the set current to the value specified in the above table. Output current is multiplied by factor 50.
|
Termocouple sensor simulation
| types |
R, S, B, J, T, E, K, N |
| range of temperature |
-250 °C - 1820 °C |
| temperature unc. |
0.4 °C - 4.0 °C |
| temperature scale
|
ITS 90, PTS 68 |
Accessories (included)
| Power line cable |
1 pc |
| Operation manual |
1 pc |
| Option 10/11 : Test cable for 1000V - 20 A, black/red |
2 pcs |
Options (extra ordered)
| Option 130-50 |
Current coil with 50 turns. Suitable for clamp A-meters testing up to 500 A. Maximal recommended output current into the coil is 10 A.
|
 |
| Option 10 |
Test cable 20A/1000V (black) |
|
| Option 11 |
Test cable 20A/1000V (red) |
|
| Option 20 |
Test cable BNC/BNC 1m |
|
| Option 30 |
Test cable BNC/banana 1m |
|
| Cable GPIB |
IEEE488/IEEE488, 2m |
|
| Cable RS-232 |
RS-232, 2m |
|
| WinQbase |
Application SW for making database of meters and for automatic meter calibration. |
|
| CALIBER |
SW module for automatic calibration of multimeters. |
|